Re: Dead Vaxstation?
* Tobias Nygren <tnn%NetBSD.org@localhost> [2016-03-15 06:16:12]:
> On Tue, 15 Mar 2016 06:09:24 -0400
> Matt Dainty <matt%bodgit-n-scarper.com@localhost> wrote:
>
> > Anything I can try? I figure the Dallas DS1287 timekeeper chip probably has
> > a dead battery by now but that wouldn't stop the machine powering up
> > would it?
>
> That's what I figured too, but it actually does prevent it from POSTing.
> My 4000/90 also appeared completely dead until I bodged a fresh lithium
> cell into the RTC, after which it came back to life.
I can confirm this was the exact problem. I extracted the DS1287 and used
a Dremel to expose the battery contacts on the chip; my multimeter
reported there was about 220-230 mV left in the internal battery prior to
severing the connection.
I've now soldered a CR2032 battery and holder to the contacts and refitted
it to my Vaxstation and now it powers up as expected.
Cheers
Matt