Hi, Derrick-- On Sep 17, 2008, at 1:56 PM, Derrick Lobo wrote:
Still getting these error.. ccd0: error 5 on component 0sd1(ahd0:0:2:0): Check Condition on CDB: 0x28 00 00 70 fc e0 00 00 10 00SENSE KEY: Hardware Error INFO FIELD: 7404777 ASC/ASCQ: No Defect Spare Location Available FRU CODE: 0x4 ccd0: error 5 on component 0Any idea what this could.. I have replaced 3 drives on the server.. This is an HP DL385 I move the drive to another location on the bay and still seethe problem...
The error is clear enough; the drive has gotten so many failed sectors that it has run out of spares and is now losing data sectors without replacement. Replace ASAP. Moving the drive to a different bay is not useful.
If you've already replaced drives before, there's likely to be a correlation with some environmental problem like inadequate cooling (if your drives run hot, above 35-40 C, they fail *much* more quickly) or perhaps a lot of dust/smoke/plaster dust/etc in the air.
Regards, -- -Chuck