NetBSD-Users archive

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index][Old Index]

Re: HDD errors.



Hi, Derrick--

On Sep 17, 2008, at 1:56 PM, Derrick Lobo wrote:
Still getting these error..

ccd0: error 5 on component 0
sd1(ahd0:0:2:0): Check Condition on CDB: 0x28 00 00 70 fc e0 00 00 10 00
SENSE KEY: Hardware Error
INFO FIELD: 7404777
ASC/ASCQ: No Defect Spare Location Available
FRU CODE: 0x4

ccd0: error 5 on component 0

Any idea what this could.. I have replaced 3 drives on the server.. This is an HP DL385 I move the drive to another location on the bay and still see
the problem...

The error is clear enough; the drive has gotten so many failed sectors that it has run out of spares and is now losing data sectors without replacement. Replace ASAP. Moving the drive to a different bay is not useful.

If you've already replaced drives before, there's likely to be a correlation with some environmental problem like inadequate cooling (if your drives run hot, above 35-40 C, they fail *much* more quickly) or perhaps a lot of dust/smoke/plaster dust/etc in the air.