tech-kern archive

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index][Old Index]

Re: regression (crash) in sysmon/acpiacad



paul%whooppee.com@localhost said:
> Since the charge value was not updating, it  might be that the ACPI
> Notify isn't working here.

For the critical shutdown, a call to _BTP might help.
But anyway, from my limited experience with process control
("SCADA") systems, it makes sense to maintain a timestamp
for the last data value read (or delivered by asynchronous
notification) and force a fresh read if it is older than
a limit defined by the provider (and possibly overridden
by the consumer).

best regards
Matthias



------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------
Forschungszentrum Juelich GmbH
52425 Juelich
Sitz der Gesellschaft: Juelich
Eingetragen im Handelsregister des Amtsgerichts Dueren Nr. HR B 3498
Vorsitzende des Aufsichtsrats: MinDir'in Baerbel Brumme-Bothe
Geschaeftsfuehrung: Prof. Dr. Achim Bachem (Vorsitzender),
Dr. Ulrich Krafft (stellv. Vorsitzender), Prof. Dr.-Ing. Harald Bolt,
Prof. Dr. Sebastian M. Schmidt
------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------


Home | Main Index | Thread Index | Old Index