On Dec 2, 2010, at 5:47 AM, Sad Clouds wrote:

Hi, on my nettop with Intel Atom D510 CPU, envstat() seems to behave a bit sporadically. If I boot the machine from cold and run envstat() it reports no drivers registered. However if I let the machine run for a few minutes and reboot it, then envstat() reports CPU temperature.

Anyone knows why NetBSD envsys does not pick up temperature sensors when booting from cold?

Which driver is it? One possibility would be that the sensor takes a while to (literally) warm up and provide valid output which an over eager driver might interpret as malfunction and therefore doesn't attach. I've seen this with the built-in thermal sensor in PowerPC G3 CPUs - up to a few minutes after power up it reads temperatures barely above freezing.