Current-Users archive

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index][Old Index]

Re: Aquantia AQC100 issues



Hi,

Seems like revision check is enough. I have A1 revision card. I
believe revision checks didn't exist at the time initial if condition
was added for fibre.

On Sat, Nov 11, 2023 at 9:50 AM Rin Okuyama <rokuyama.rk%gmail.com@localhost> wrote:
>
> Hi Andrius,
>
> If you still have this AQC100 in working condition, can you try this patch?
>
> https://gist.github.com/rokuyama/ab6ba1a0fac7fa15f243d63a99e14f33
>
> I've collected three fibre aq(4) variants (all rev 2), and link status
> interrupts work just fine for me. I think that link intr did not work for
> you, not due to fibre variant, but hardware revision. If this is correct,
> the patch above should work...
>
> Thanks,
> rin
>
> On Fri, Apr 24, 2020 at 7:10 AM Andrius V <vezhlys%gmail.com@localhost> wrote:
> >
> > Thank you for the help and updated code. Retested on current branch,
> > works as expected. Possibly worth to mention AQC100 in  aq.4 as well?
> >
> >
> > On Thu, Apr 23, 2020 at 8:33 AM Ryo Shimizu <ryo%nerv.org@localhost> wrote:
> > >
> > >
> > > >Yes, the patch solves the problem. Linked is up immediately after the boot.
> > >
> > > I'm relieved. In the interim, I'll commit a fix that always polling linkstat when FIBRE.
> > >
> > > thanks,
> > > --
> > > ryo shimizu
> >


Home | Main Index | Thread Index | Old Index