On Thu, Sep 25, 2003 at 12:37:19PM -0500, Gunther Schadow wrote:
> Johnny Billquist wrote:
> >To make a short answer: the unibus termination is *vital*.
> >If you fail diagnostics with it inserted, it's not because of the
> >termination, but because some problem in your Unibus don't show up
> >otherwise. The termination should be in the last slot, in AB.
> 
> So, I need grants and NPG grants in front of the terminator?

*every* slot on the Unibus must have either:

1) A card
2) A continuity ("grant") card
3) if a slot that is wired for VAX DMA, a VAX DMA card or a *VAX DMA
   continuity card*.
4) A terminator

The terminator must go in the last slot.

Thor