Subject: Re: Unexpected problems, part 2
To: Brian Chase <vaxzilla@jarai.org>
From: Lord Isildur <mrfusion@uranium.vaxpower.org>
List: port-vax
Date: 05/19/2003 09:36:27
Yes, to clarify on this point, if you power the vs up with the console
not connected, then it will not halt on breaks. ^p should still work
when you need to halt it, though.
Isildur
On Mon, 19 May 2003, Brian Chase wrote:
> On Mon, 19 May 2003, Blaz Antonic wrote:
>
> > If i understand correctly the PC sends a break when it boots up (powers
> > up, it didn't happen when it was just rebooting) and this makes my Vax
> > crash back to console prompt. Cable is ALWAYS attached to the PC and it
> > is rebooted (or started) every now and then, asynchronously with what
> > happens to Vax. So the only way around this problem is not to have PC
> > power up while Vax is running the OS (i hate 1 GB filesystem checks) ?
>
> Another option is to leave the serial cable disconnected until you
> need it. That does require some error prone "human intervention" steps
> to come into play to work. The next time this happens, try entering
> the CONTINUE command at the >>> prompt to see if things pick up from
> where they were before the halt.
>
> -brian.
>