Subject: Re: disks on a 4000/600A or 700A
To: Jochen Kunz <jkunz@unixag-kl.fh-kl.de>
From: Tom Ivar Helbekkmo <tih@eunetnorge.no>
List: port-vax
Date: 04/09/2003 13:48:28
Jochen Kunz <jkunz@unixag-kl.fh-kl.de> writes:
>> Someplace (I'll have to look for it), there's a way to
>> increase the count up to 7(?).
> It is simple. Configure every disk at a separate CSR and include
> apropriate
> uda* at uba? csr <insert CSR here> # UDA50/RQDX?
> lines in the kernel config file.
And to get them all (and other options) correctly configured, so that
original DEC operating systems will automatically recognize them, use
my 'sysgen' utility, in pkgsrc/sysutils/sysgen. For instance:
athene:tih> sysgen
Type device names one per line, optionally followed
by a comma and a repeat count. Finish with EOF.
tqk50
deqna
uda,7
dhv11
Table of standard DEC assignments for configuration:
DEVICE CSR VECTOR
-------------------------
TQK50 774500 0260
DEQNA 774440 0120
UDA 772150 0154
UDA 760334* 0300*
UDA 760340* 0304*
UDA 760344* 0310*
UDA 760350* 0314*
UDA 760354* 0320*
UDA 760360* 0324*
DHV11 760500* 0330*
CSRs and vectors marked '*' are in floating space.
-tih
--
Tom Ivar Helbekkmo, Senior System Administrator, EUnet Norway
www.eunet.no T: +47-22092958 M: +47-93013940 F: +47-22092901