Subject: RE: Instability problems
To: 'Lord Isildur' <mrfusion@uranium.vaxpower.org>
From: Antonio Carlini <arcarlini@iee.org>
List: port-vax
Date: 01/30/2003 18:36:31
> yes, there is a setting for automatic restart. i'll have to check my=20
> manual (which is not anywhere near me) to know for sure, but=20
> you could just try changing it to values other than 0 and 1,=20
> like 2 and 3, and see what=20
> happens.. or someone on the list who actually knows it might point it=20
> out.. (this is of course the value for the HALT variable)

1 is automatic restart
2 is automatic reboot
3 is automatic halt

So=20
         >>> SET HALT 2
should do it. Given that the VS3100-76 has
no battery backed RAM, I expect that SET HALT 1
will be equivalent (although it may take the box
a second or so to realise that a restart is impossible).

Antonio
=20
--=20

---------------
Antonio Carlini             arcarlini@iee.org