Subject: Re: uVAX 3100/30 NIC woes
To: None <port-vax@netbsd.org>
From: Fernando Carnero <fcarnero@hotmail.com>
List: port-vax
Date: 05/28/2001 17:28:08
>Hello,
>
>I recently moved my MicroVAX 3100/30 to a different location in my
>room.  After doing so, the NIC no longer seems to work, giving the
>message:
>
>?? 001	9	NI 0172
>
>on boot.  As I'm netbooting NetBSD, this is a problem.
>
>I'm using an AUI-->10BaseT transceiver right now; the switch is in the
>correct position, it seems.  I have tested the cable from the hub to the
>AUI transceiver, so I can eliminate that from the possible problem list.

Tyler:

Probe this:

1- Move the AUI switch to BNC
2- Put in the BNC a T connector with two 50 ohm terminator.
3- Reboot.

If the error dissaper then the problem is in the tranciver or the AUI 
connector.

Probe in any other site the transciver, if its work, the problem is in the 
VAX. Probably a pico-fuse broken in the ethernet converter.

Put attention in ground connections in the VAXC and in false contacts in the 
AUI.

Other problem: the AUI/BNC swith broken o move from AUI to BNC.


Best R....

Fernando




_________________________________________________________________________
Get Your Private, Free E-mail from MSN Hotmail at http://www.hotmail.com.