Subject: Re: VAXStation 4000/90 install
To: None <Patrice.Lespagnol@obs-nancay.fr>
From: None <jkunz@unixag-kl.fh-kl.de>
List: port-vax
Date: 01/23/2001 11:15:05
On 23 Jan, Patrice  Lespagnol wrote:

>         701856+1205116+145624=0x1f51f8
> then nothing happen.
Do you use the local framebuffer console? This is not supported. You
have to switch S3 on the front to the upper position and connect a
serial terminal to the printerport. (The six pin modified RJ plug.) See
http://anacin.nsc.vcu.edu/~jim/mvax/pinouts.html 
for pinouts.
-- 



tschüß,
         Jochen

Homepage: http://www.unixag-kl.fh-kl.de/~jkunz/