Subject: vax etc serial port documentation
To: None <>
From: None <>
List: port-vax
Date: 12/22/2000 11:05:43
> > Are the VAXstation 3100 diagnostic LEDs documented online anywhere?
> > So far I have only seen specific answers to questions about them.
> >
> > I have problems with two VAXstation 3100 (m30 and m38) with serial
> > console.
> > They were ok until one was rebooted and never came up again, and the other
> > was powered off.
> > Afterwards, both were stuck with LED 7 and 6 on, and LED 5 blinking
> > occasionally.
>
> See http://www.nvg.ntnu.no/data/hardware/vax3100-leds.html
Maybe this should be at the netbsd.org hardware pages?
> I checked a bit more, and it goes:
> 1111 1111
> 1111 0000
> back: 1110 0000
> 1101 0000 (very fast)
> 1100 0000
> goto back;
>
> What am I to make of it?
>
> Bad serial device?
Figured it out after a while.
The serial port hardware were no longer content with RS-232 and would only
accept DEC-423. (Tested on a VT340+)
Maybe there is a need for more docs/link about DEC-423 and RS-423?
Regards,
Roar