> > I've just run across the nvram clearing procedure in the VAXstation 3100
> > Model 76 Maintenance Guide (EK-VS31M-MG.002).
> > 
> > 1, Power off
> > 
> > 2. Remove the socketed Dallas chip. It is located behind and between the 
> >     two banks of memory sockets. It has a white picture of an alarm on it.
> >     Note the orientation carefully!
> > 
> > 3. Place the chip on the PSU conductive surface for one to three seconds.
> >     This briefly shorts the internal battery and resets the password state
> >     to disabled.
> > 
> >     THE MANUAL HAS A BIG BOLD WARNING: IF YOU SHORT THE CHIP
> >     INTERNAL BATTERY FOR LONGER THAN THREE SECONDS MAY CAUSE
> >     PREMATURE BATTERY FAILURE.
> > 
> > 4. Put the chip back in its socket, observing correct orientation.
> > 
> > 5. Power up and breath a big sigh of relief when it all works.
> 