Subject: Re: Stuck prom on VS3100 M76 --- how to reset?
To: Carlini, Antonio <Antonio.Carlini@cabletron.com>
From: NetBSD Bob <nbsdbob@weedcon1.cropsci.ncsu.edu>
List: port-vax
Date: 08/09/2000 11:52:31
> I've just run across the nvram clearing procedure in the VAXstation 3100
> Model 76 Maintenance Guide (EK-VS31M-MG.002).
>
> 1, Power off
>
> 2. Remove the socketed Dallas chip. It is located behind and between the
> two banks of memory sockets. It has a white picture of an alarm on it.
> Note the orientation carefully!
>
> 3. Place the chip on the PSU conductive surface for one to three seconds.
> This briefly shorts the internal battery and resets the password state
> to disabled.
>
> THE MANUAL HAS A BIG BOLD WARNING: IF YOU SHORT THE CHIP
> INTERNAL BATTERY FOR LONGER THAN THREE SECONDS MAY CAUSE
> PREMATURE BATTERY FAILURE.
>
> 4. Put the chip back in its socket, observing correct orientation.
>
> 5. Power up and breath a big sigh of relief when it all works.
Excellent!
Someone who has control of the NetBSD VAX webpages PLEEEEZE make sure this
kind of info gets posted in a clearly found location. It is basic must-have
fare.....
Many Thanks, Antonio!
Bob