Subject: Re: MicroVAX 3100 netboot fails
To: None <port-vax@netbsd.org>
From: George Harvey <fr30@dial.pipex.com>
List: port-vax
Date: 08/08/2000 21:23:06
On 05-Aug-00, Michael Kukat wrote:
>Hi !
>On Sat, 5 Aug 2000, George Harvey wrote:
[ snip ]
>> > boot netbsd
>> 619520+1118928+151904 total=0x1cd834
>>
>> /** no further output after this! **/
>Your console is redirected to the wrong media. Try plugging another terminal
>to port 3 of your machine.
I've tried the 3 MMJ ports, and even the DB-25 modem port, but there
is no response from any of them after the kernel load finishes. Are
there any special requirements for the console? (I am using a VT220
terminal emulator running at 9600/8/N/1).
I have also tried booting from floppy (RX23, 1.4MB) using the
'boot.fs' image but that gave me a stack trace. I have included
the 'sh ver' and 'sh dev' output below along with the floppy boot
stack trace.
If the netbooted kernel is running, but I just can't see the
console, what additional entries would I need in /dev to be
able to start the network (there is only an entry for the
console at present).
Thanks,
George
>>> show dev
VMS/VMB ULTRIX ADDR DEVTYP NUMBYTES RM/FX WP DEVNAM REV
------- ------ -------- ------ -------- ----- -- ------ ---
ESA0 SE0 08-00-2B-1A-E0-BB
DKA300 RZ3 A/3/0/00 DISK 104 MB FX RZ23 0A18
DKA500 RZ5 A/5/0/00 DISK ........ RM RX23 0054
...HostID.... A/6 INITR
...HostID.... B/6 INITR
>>> sh ver
KA41-D V1.1C6-17B-V6.2-263
PST: 17B
CON: 1C6
VMB: V6.2
ROM: 263
>>> boot dka500
-DKA500DKBTDRIVER halting at relative address 041A DKBTDRIVER base addr =
00001
754
REGISTERS R0: 00000054 R1: 00000003 R2: 00000000 R3: 00080018
R4: 00000020 R5: 00000001 R6: 003FE070 R7: 200C0080
R8: 00000200 R9: 00000000 R10: 00080018 R11: 00000001
CMDBUF: 00000800 00000306 SENSE_BUF: 0E000000 00050070
STATUS_BUF: 02 SENSE_STATUS: 00
MSG_IN_BUF: 00 SENSE_MSG_IN: 00 SENSE_INDEX: FFFFFFFF
USER_BUF_ADDR: 00080018 TOTAL_XFER_COUNT: 00000000 BYTES_LEFT: 00000200
PG_TABLE_PTR: 00000000 BASE_VPN: 00000400 BUFFER_PTR: 00080018
MAP_MODE: 00000000
STACK: 00001B55
00002568
00000000
00001E1A
00001D64
000016DF
84 FAIL
>>>