Subject: Re: VS3100/M76 without MMU !?
To: None <port-vax@netbsd.org>
From: None <jkunz@unixag-kl.fh-kl.de>
List: port-vax
Date: 05/22/2000 00:02:03
On 21 May, Screenager.2000@gmx.net wrote:

> when I turn on my VS3100/M76 the gadget does some tests and gives me the
> following unusual result:
> KA-43 V1.2
>  ..... A_ .......  4_ 3_ 2_ 1?
This looks usual to me. My m76 says the same:
--- snip ---
KA43-A  V1.2

F...E...D...C...B...A_..9...8...7...6...5...4_..3_..2_..1...
--- snip ---

> This means items 4, 3, and 2 are missing which should be ok. But the item
> A which is, according to the FAQs I found on the Net, the MMU is missing too
> !
> Who can tell me what's wrong ?
> Any ideas are appreciated.
From the VAXstation 3100 Model 76 Owner's Guide, page 7-2:
--- snip ---
An underscore and two dots (_..) indicate that the optional device is
not installed or that the device has not been tested. 
--- snip ---

BTW: Thanks to Christophe for the manual and the hosting of the nice
VAX-Geek Meeting. :-) 
-- 



tschüß,
         Jochen

Homepage: http://www.unixag-kl.fh-kl.de/~jkunz/