Subject: RA81 front panel error codes.
To: None <port-vax@netbsd.org>
From: Sergey Svishchev <svs@ropnet.ru>
List: port-vax
Date: 06/06/1999 23:16:23
G'day,
Front panel code is displayed on 6 lamps: RUN/STOP FAULT RDY WRITE_PROT A B
FAULT should be always on (except in "DC Low" condition.)
0x11 Spin error
0x12 Microprocessor fault
0x13 SDI error
0x14 Master/slave error
0x15 Servo fine positioning error
0x16 Servo coarse positioning error
0x17 Spindle motor interlock error
0x18 Servo or HDA overtemp error
0x19 R/W unsafe error
0x1a R/W command error
0x1b Servo/HDA interlock error
0x1c Servo/microprocessor interlock error
0x1d Read/write microprocessor interlock error
0x1e Control panel/microprocessor interlock error
0x1f Personality/microprocessor interlock error
0x30 Index error
0x31 Write and bad embedded data
0x32 Drive disabled by DD bit
0x33 Write enable and write protect asserted error
0x34 Servo diagnostic test error
0x35 R/W diagnostic test error
0x36 Diagnostic idle loop test error
0x2f DC low
0x3f Microprocessor hardcore test error
--
Sergey Svishchev -- svs{at}ropnet{dot}ru