Subject: Re: Pinout of printerprot on VS3100 M38 ?
To: None <port-vax@netbsd.org>
From: Jesper Frank Nemholt <jfn@dassic.com>
List: port-vax
Date: 10/13/1998 20:26:27
Gunnar Helliesen wrote:
>
> Michael Kukat wrote:
> >
>
> > Ok, serial (MMJ) pinout comes the next days, i'll find it out.
>
> Pin # Signal name CCIT # Mnemonic
> -----------------------------------------------------------
> 1 Data Terminal Ready 108.2 DTR
> 2 Transmit Data 104 Tx
> 3 Signal Ground 102 SG
> 4 Receive Common --- RxC
> 5 Receive Data 103 Rx
> 6 Data Set Ready 107 DSR
Thanks alot. I've now 'made contact' with both machines :)
Only problem is that when I write a command, every character gets echoed
twice on my terminal screen even though I've disabled local echo.
l8r/Jspr
--
Jesper Frank Nemholt Tel : +45 75 82 52 56
Pilevaenget 23 2. MF Fax : +45 75 82 52 69
DK-7100 Vejle WWW : http://dassic.com/users/jfn/
Denmark, Planet Earth... E-Mail: mailto:jfn@dassic.com
He who throws mud loses ground.