Hi,
Thanks for testing!
> Here is what I got:
> [ 1.000000] adm1026hm0 at iic0 addr 0x2e: ADM1026 hardware monitor: rev. 0x4, step. 0x5
> [ 1.000000] adm1026hm0: 8 fans, 3 temperatures, 15 voltages
> [ 1.000000] adm1026hm0 at iic0 addr 0x2e: ADM1026 hardware monitor: rev. 0x4, step. 0x5
> [ 1.000000] adm1026hm0: 7 fans, 3 temperatures, 15 voltages
>
> I think that spans two different boots though. 8 fans and then 7 fans ?
I added a patch to correctly set the number of fans on the V240. The V210
has 4 system fans, but the V240 has 3. We previously reported 8 for both.
Without that and with the limits code, you would see a warning that the
4th system fan was at 0 speed.
> Let me know what else I can look at or test.
Dmesg looks fine, and I guess no warnings about over limits at boot time?
Regards,
Julian
--