Subject: cpu0: NMI: system interrupts...
To: None <port-sparc@netbsd.org>
From: Mattias Karlsson <mattias.karlsson@nocom.se>
List: port-sparc
Date: 07/29/2003 09:05:48
Anyone figured out what this mean?

Jul 29 02:08:45 virgo /netbsd: cpu0: NMI: system interrupts: 
40000000<VME=0,SBUS=0,ME>

It didn't cause much problems, except making a ircd process hang.
I did notice it was slow when logging into it tho, it has worked great
since I rebooted it.  And I have never seen this on this machine before.

I'm not on this list, so keep my address in to/cc.


Regards,
Mattias.



DMESG:

Copyright (c) 1996, 1997, 1998, 1999, 2000, 2001, 2002
     The NetBSD Foundation, Inc.  All rights reserved.
Copyright (c) 1982, 1986, 1989, 1991, 1993
     The Regents of the University of California.  All rights reserved.

NetBSD 1.6.1 (GENERIC) #0: Wed Apr  9 03:02:04 UTC 2003
 
autobuild@tgm.daemon.org:/autobuild/netbsd-1-6/sparc/OBJ/autobuild/netbsd-1-6/src/sys/arch/sparc/compile/GENERIC
total memory = 65128 KB
avail memory = 56760 KB
using 839 buffers containing 3356 KB of memory
bootpath: 
/iommu@0,10000000/sbus@0,10001000/espdma@4,8400000/esp@4,8800000/sd@3,0
mainbus0 (root): SUNW,SPARCstation-4
cpu0 at mainbus0: MB86904 @ 110 MHz, on-chip FPU
cpu0: 16K instruction (32 b/l), 8K data (16 b/l): cache enabled
obio0 at mainbus0
clock0 at obio0 slot 0 offset 0x200000: mk48t08: hostid 80799a3e
timer0 at obio0 slot 0 offset 0xd00000: delay constant 52
zs0 at obio0 slot 0 offset 0x100000 level 12 softpri 6
zstty0 at zs0 channel 0
zstty1 at zs0 channel 1
zs1 at obio0 slot 0 offset 0x0 level 12 softpri 6
kbd0 at zs1 channel 0: baud rate 1200 (console input)
ms0 at zs1 channel 1: baud rate 1200
slavioconfig at obio0 slot 0 offset 0x800000 not configured
auxreg0 at obio0 slot 0 offset 0x900000
power0 at obio0 slot 0 offset 0x910000 level 2
fdc0 at obio0 slot 0 offset 0x400000 level 11 softpri 4: chip 82077
fd0 at fdc0 drive 0: 1.44MB 80 cyl, 2 head, 18 sec
iommu0 at mainbus0 addr 0x10000000: version 0x4/0x0, page-size 4096, 
range 64MB
sbus0 at iommu0: clock = 22 MHz
dma0 at sbus0 slot 4 offset 0x8400000: dma rev 2
esp0 at dma0 slot 4 offset 0x8800000 level 4: ESP200, 40MHz, SCSI ID 7
scsibus0 at esp0: 8 targets, 8 luns per target
bpp0 at sbus0 slot 4 offset 0xc800000 level 2 (ipl 3): dma rev 2
ledma0 at sbus0 slot 4 offset 0x8400010: dma rev 2
le0 at ledma0 slot 4 offset 0x8c00000 level 6: address 08:00:20:79:9a:3e
le0: 8 receive buffers, 2 transmit buffers
tcx0 at sbus0 slot 2 offset 0x800000 level 5 (ipl 9): SUNW,tcx, 1152 x 
900, id 0, rev 2, sense 0 (console)
tcx0: attached to /dev/fb
power-management at sbus0 slot 3 offset 0xa000000 not configured
scsibus0: waiting 2 seconds for devices to settle...
sd0 at scsibus0 target 3 lun 0: <CONNER, CFP1080E SUN1.05, 5150> SCSI2 
0/direct fixed
sd0: 1030 MB, 3658 cyl, 6 head, 96 sec, 512 bytes/sect x 2110812 sectors
sd0: sync (100.0ns offset 15), 8-bit (10.000MB/s) transfers, tagged queueing
cd0 at scsibus0 target 6 lun 0: <TOSHIBA, XM-4101TASUNSLCD, 1755> SCSI2 
5/cdrom removable
cd0: async, 8-bit transfers
Kernelized RAIDframe activated
root on sd0a dumps on sd0b
root file system type: ffs