Subject: Re: troubles with DECstation 5000/240 (another one)
To: None <talon16m@hotmail.com>
From: Daniel Senderowicz <daniel@synchrods.synchrods.COM>
List: port-pmax
Date: 01/15/2000 22:24:16
>>>> test
>> ?TFL: 3/ni/ext-lb (3:(xmt [00000006, 00000040] cable)) [KN03-AA]
>>
>
> I'm fairly certain this means that you have one or more of the following:
> 1.) have no transceiver / loopback connected
> 2.) are using 10Base2 (BNC) and don't have it terminated properly (50
>ohm t-res on both ports of a BNC T
> 3.) have no link
> 4.) excessive network collisions from somewhere else on the network
> 5.) wrong type / resistance or bad cable.
I have no link. The port (not BNC) is not connected to any
network.
>
>>>> test-scc-m
>> ?TFL: 3/scc/pins (2:Ln 2 strtup R-00 xptd=00 actl=20 | 4-5|) [KN03-AA]
>
> scc is the serial controller, sounds like it doesn't like whatever you
>have plugged into port 2. Whether port 2 is com port 2 on the back of the
>unit or com port 2 the keyboard/mouse port, I couldn't tell you. I'm
>guessing it is port two on the back of the unit.
I have a V.90 modem connected to port 2. I wonder if all modems
give this kind of message or just this one (Explorer V.90 Ex).
Incidentally I was having problems using rates above 38400. Does
anybody have problems communicating above 57600, e.g. 115200?
Thanks,
Dan