Subject: Promise Ultra66 card on Beige G3
To: None <port-macppc@netbsd.org>
From: Dmitry N. Vladimirov <mgmttu@mail.ru>
List: port-macppc
Date: 04/08/2006 22:36:17
Hi guys.
I'm not an not an expert on the NetBSD on macppc (rather newbie) and i
wanted to get use out of the G3 was getting dusty.
I unstalled the NetBSD 2.0.2 and it worked fine.
After that I trying to get more out of it and insert the Promise
Ultra66 i was using on my PC into it (I'm running samba on it and I
want to make it faster).

Per the dmesg.boot (I attached below) the card is being identified correctly
(or am I wrong?).
But despite of any tries the I cannot see drive attached to it (though
when i connect it to the usual IDE connector on the motherboard, it
worked fine - i also attached the output of the "atactl wd2 identify"
command - "wd2" is the disk I'm trying to see attached to the Promise
controller and "wd2" is its name when it's attached to the "USUAL" IDE
on the motherboard).

Could you give any advices or suggestions?

It'd be greatly appreciated.

Sincerely,
Dmitry

--------------------------------- dmesg.boot ----------------------
NetBSD 2.0.2 (GENERIC) #0: Tue Mar 22 16:19:08 UTC 2005
        jmc@faith.netbsd.org:/home/builds/ab/netbsd-2-0-2-RELEASE/macppc/20=
0503220140Z-obj/home/builds/ab/netbsd-2-0-2-RELEASE/src/sys/arch/macppc/com=
pile/GENERIC
total memory =3D 192 MB
avail memory =3D 178 MB
mainbus0 (root)
cpu0 at mainbus0: 750 (Revision 2.2), ID 0 (primary)
cpu0: HID0 8290c0a4<EMCP,ECLK,DOZE,DPM,ICE,DCE,SGE,BTIC,BHT>
cpu0: 237.29 MHz, no-parity 512KB WB L2 cache (PB SRAM) at 2:1 ratio
grackle0 at mainbus0
pci0 at grackle0 bus 0
pci0: i/o space, memory space enabled
pchb0 at pci0 dev 0 function 0
pchb0: Motorola MPC106 "Grackle" Host Bridge (rev. 0x40)
pdcide0 at pci0 dev 13 function 0
pdcide0: Promise Ultra66/ATA Bus Master IDE Accelerator (rev. 0x01)
pdcide0: bus-master DMA support present
pdcide0: primary channel configured to native-PCI mode
pdcide0: using irq 23 for native-PCI interrupt
atabus0 at pdcide0 channel 0
pdcide0: secondary channel configured to native-PCI mode
atabus1 at pdcide0 channel 1
ex0 at pci0 dev 15 function 0: 3Com 3c905C-TX 10/100 Ethernet with mngmt (r=
ev. 0x74)
ex0: interrupting at irq 25
ex0: MAC address 00:04:79:66:79:44
bmtphy0 at ex0 phy 24: Broadcom 3c905C internal PHY, rev. 6
bmtphy0: 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, auto
obio0 at pci0 dev 16 function 0: addr 0xf3000000
mesh0 at obio0 offset 0x10000 irq 12: 50MHz, SCSI ID 7
scsibus0 at mesh0: 8 targets, 8 luns per target
bm0 at obio0 offset 0x11000 irq 42,33: address 00:05:02:b5:98:04
zsc0 at obio0 offset 0x13000: irq 15,16
zstty0 at zsc0 channel 0
zstty1 at zsc0 channel 1
davbus at obio0 offset 0x14000 not configured
swim3 at obio0 offset 0x15000 not configured
nvram0 at obio0 offset 0x60000
wdc0 at obio0 offset 0x20000 irq 13: DMA transfer
atabus2 at wdc0 channel 0
wdc1 at obio0 offset 0x21000 irq 14: DMA transfer
atabus3 at wdc1 channel 0
adb0 at obio0 offset 0x16000 irq 18: 0 targets
aed0 at adb0 addr 0: ADB Event device
ofb0 at pci0 dev 18 function 0: ATI Technologies 3D Rage Pro
ofb0: 1024 x 768, 8bpp
wsdisplay0 at ofb0 kbdmux 1: console (std, vt100 emulation)
wsmux1: connecting to wsdisplay0
scsibus0: waiting 2 seconds for devices to settle...
wd0 at atabus2 drive 0: <QUANTUM FIREBALL640A>
wd0: drive supports 8-sector PIO transfers, LBA addressing
wd0: 612 MB, 1244 cyl, 16 head, 63 sec, 512 bytes/sect x 1253952 sectors
wd0: drive supports PIO mode 4, DMA mode 2
wd1 at atabus2 drive 1: <SAMSUNG WINNER-3 WN31273A(1.27GB)>
wd1: drive supports 16-sector PIO transfers, LBA addressing
wd1: 1212 MB, 2464 cyl, 16 head, 63 sec, 512 bytes/sect x 2483712 sectors
wd1: drive supports PIO mode 4, DMA mode 2
wd0(wdc0:0:0): using PIO mode 4, DMA mode 2 (using DMA data transfers)
wd1(wdc0:0:1): using PIO mode 4, DMA mode 2 (using DMA data transfers)
atapibus0 at atabus3: 2 targets
cd0 at atapibus0 drive 0: <HITACHI CDR-8130, , 0021> cdrom removable
cd0: drive supports PIO mode 4, DMA mode 2
cd0(wdc1:0:0): using PIO mode 4, DMA mode 2 (using DMA data transfers)
boot device: wd0
root on wd0a dumps on wd0b
root file system type: ffs
----------- end of dmesg.boot --------------------

------------ output of the "atactl wd2 identify" command -------
Model: WDC WD200BB-00CLB0, Rev: 05.04E05, Serial #: WD-WMAAR1227306
Device type: ATA, fixed
Device capabilities:
        DMA
        LBA
        ATA standby timer values
        IORDY operation
        IORDY disabling
Device supports following standards:
ATA-1 ATA-2 ATA-3 ATA-4 ATA-5
Command set support:
        READ BUFFER command
        WRITE BUFFER command
        Host Protected Area feature set
        look-ahead
        write cache
        Power Management feature set
        Security Mode feature set
        SMART feature set
        Automatic Acoustic Management feature set
        SET MAX security extension
        DOWNLOAD MICROCODE command
Command sets/features enabled:
        look-ahead
        write cache
------------ output of the "atactl wd2 identify" command -------







--=20
=D1 =F3=E2=E0=E6=E5=ED=E8=E5=EC,
 Dmitry                          mailto: press Reply button