Subject: Re: Oops: pciide0:0:0: lost interrupt
To: Donald Lee <MacPPC@caution.icompute.com>
From: Manuel Bouyer <bouyer@antioche.eu.org>
List: port-macppc
Date: 03/12/2004 22:39:34
On Thu, Mar 11, 2004 at 11:56:16PM -0600, Donald Lee wrote:
> Hi everybody
>
> I just installed a third disk on my Beige G3. All are ATA
> disks, two are Cuda V (80 GB) and the new one is a Cuda 7200.7 @200 GB.
>
> wd0 is hooked up to the "internal" ide, and disks wd1 and wd2
> are connected to a PCI card
> (pciide0 at pci0 dev 15 function 0: Promise Ultra133/ATA Bus Master IDE Accelerator (rev. 0x02))
>
> One disk is on each of the two ATA channels on the card.
>
> I tried to beat on the disks, with some heavy I/O reading from wd1 and writing
> to wd2.
>
> This seems to work, sort of. The I/O does not seem to actually
> fail, but it does seem to 'hang' periodically.
>
> I get lots of these:
>
> Mar 11 23:27:40 grace /netbsd: type: ata tc_bcount: 8192 tc_skip: 0
> Mar 11 23:27:49 grace /netbsd: pciide0:0:0: lost interrupt
> Mar 11 23:27:49 grace /netbsd: type: ata tc_bcount: 8192 tc_skip: 0
> Mar 11 23:27:50 grace /netbsd: pciide0:1:0: lost interrupt
> Mar 11 23:27:50 grace /netbsd: type: ata tc_bcount: 8192 tc_skip: 0
> Mar 11 23:28:31 grace /netbsd: pciide0:0:0: lost interrupt
> Mar 11 23:28:31 grace /netbsd: type: ata tc_bcount: 65536 tc_skip: 0
> Mar 11 23:28:31 grace /netbsd: pciide0:1:0: lost interrupt
> Mar 11 23:28:31 grace /netbsd: type: ata tc_bcount: 65536 tc_skip: 0
> Mar 11 23:28:40 grace /netbsd: pciide0:0:0: lost interrupt
> Mar 11 23:28:40 grace /netbsd: type: ata tc_bcount: 65536 tc_skip: 0
Are you sure your power supply is strong enouth to feed 3 drives ?
I had this problem in a server, which stopped when I s remplaced the power
supply with a stronger one.
--
Manuel Bouyer <bouyer@antioche.eu.org>
NetBSD: 26 ans d'experience feront toujours la difference
--