NetBSD-Bugs archive

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index][Old Index]

Re: port-amd64/46833: NetBSD 6.0_BETA2 shutdowns under load



The following reply was made to PR port-amd64/46833; it has been noted by GNATS.

From: Manuel Bouyer <bouyer%antioche.eu.org@localhost>
To: gnats-bugs%NetBSD.org@localhost
Cc: port-amd64-maintainer%NetBSD.org@localhost, 
gnats-admin%NetBSD.org@localhost,
        netbsd-bugs%NetBSD.org@localhost, ftigeot%wolfpond.org@localhost
Subject: Re: port-amd64/46833: NetBSD 6.0_BETA2 shutdowns under load
Date: Sun, 26 Aug 2012 18:57:08 +0200

 On Sat, Aug 25, 2012 at 11:35:02AM +0000, Martin Husemann wrote:
 > The following reply was made to PR port-amd64/46833; it has been noted by 
 > GNATS.
 > 
 > From: Martin Husemann <martin%duskware.de@localhost>
 > To: gnats-bugs%NetBSD.org@localhost
 > Cc: 
 > Subject: Re: port-amd64/46833: NetBSD 6.0_BETA2 shutdowns under load
 > Date: Sat, 25 Aug 2012 13:31:50 +0200
 > 
 >  On Sat, Aug 25, 2012 at 07:50:05AM +0000, Francois Tigeot wrote:
 >  >  [ipmi0]
 >  [..]
 >  >          Planar Temp:    43.184   95.407   90.385    8.034    3.013 degC
 >  >        Ambient Temp2:    27.116   47.201   42.180    8.034    3.013 degC
 >  >                Temp6:    43.184   47.201   42.180    8.034    3.013 degC
 >  >                Temp5:    35.150   47.201   42.180    8.034    3.013 degC
 >  
 >  The critical/warning thresholds look all completely bogus, I can believe
 >  the actual temperatures. Bugs in the SMBIOS?
 
 I have these values on a Dell poweredge 2950:
                        Current  CritMax  CritMin  CritCap     Unit
       Ambient Temp:     26.111   47.201    3.013              degC
 And a recent supermicro server:
                        Current  CritMax  WarnMax  WarnMin  CritMin  Unit
           PCH Temp@:    43.184   95.407   90.385   -5.021   -8.034 degC
         Peripheral :    28.120   77.330   75.321   -5.021   -7.030 degC
         System Temp:    23.098   77.330   75.321   -5.021   -7.030 degC
 
 So Francois's values don't look so bogus to me.
 It would be interesting to know what temp5 and temp6 are connected to.
 Maybe there limits are set too low.
 
 Francois, ipmitool from pkgsrc is working over the network if you have
 the BMC IP address configured. If you have a drac card, you should also
 be able to find temperatures here.
 
 -- 