NetBSD-Bugs archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index][Old Index]
Re: port-amd64/46833: NetBSD 6.0_BETA2 shutdowns under load
The following reply was made to PR port-amd64/46833; it has been noted by GNATS.
From: mlelstv%serpens.de@localhost (Michael van Elst)
To: gnats-bugs%netbsd.org@localhost
Cc:
Subject: Re: port-amd64/46833: NetBSD 6.0_BETA2 shutdowns under load
Date: Sat, 25 Aug 2012 08:16:28 +0000 (UTC)
ftigeot%wolfpond.org@localhost (Francois Tigeot) writes:
Hi,
> Current CritMax WarnMax WarnMin CritMin Unit
> Temp6: 43.184 47.201 42.180 8.034 3.013 degC
> Temp5: 48.205 47.201 42.180 8.034 3.013 degC
Temp6 exceeds WarnMax
Temp5 exceeds CritMax
powerd will shut down the machine when a sensor goes 'critical'.
Maybe the sensors do not read out correctly or NetBSD assumes a wrong
conversion function. Can you verify that your your server really isn't
running too hot? Often you can see the sensor readouts in BIOS or
through IPMI.
N.B. the thresholds look like being tuned for operation in a real
air-conditioned and cooled computer center. Shutting down the machine
when the cooling fails seems to be reasonable to me.
--
--
Michael van Elst
Internet: mlelstv%serpens.de@localhost
"A potential Snark may lurk in every tree."
Home |
Main Index |
Thread Index |
Old Index