Currently, Hayes ESP in ns16550 compat mode is configured by magical
option COM_HAYESP. But I would like to do it by adding glue device
specifing actual locater, i.e. write in config file like this:
hayesp0 at isa? port 0x280 irq 5
com* at hayesp? port 0x3e8
How about?
enami.