Subject: Re: raidframe, cgd and parity errors
To: None <tech-kern@NetBSD.org>
From: der Mouse <mouse@Rodents.Montreal.QC.CA>
List: tech-kern
Date: 05/08/2005 20:27:24
>> Don't the shutdown hooks get run in the reverse order that they are
>> established?
> Hmmm, yes. This works.
Only if you establish a separate shutdown hook for each instance of
(say) cgd or vnd. After all, it's entirely possible to have cgd atop
vnd and vnd atop cgd both at once on the same machine (different
"disks", to be sure); no single compile-time, nor even boot-time, order
can possibly be right.
/~\ The ASCII der Mouse
\ / Ribbon Campaign
X Against HTML mouse@rodents.montreal.qc.ca
/ \ Email! 7D C8 61 52 5D E7 2D 39 4E F1 31 3E E8 B3 27 4B