Subject: Re: test of new powerdown facility
To: Wilko Bulte <>
From: Matthew Jacob <>
List: tech-kern
Date: 06/11/1998 15:27:11
Wilko Bulte wrote:
> You should be able to send SCSI WRITE commands with the immediate bit
> (I think it's called) set. This should force a write all the way to the
> platter and only then reporting I/O complete back to the host.
> You need the SCSI specs to get the details on this.

FUA (Force Unit Access)