Subject: Re: disks on a 4000/600A or 700A
To: Jochen Kunz <jkunz@unixag-kl.fh-kl.de>
From: Lyle Bickley <lbickley@bickleywest.com>
List: port-vax
Date: 04/07/2003 13:52:50
Very cool. Thanks to everyone who responded to my questions!!!

Cheers,
Lyle

On Monday 07 April 2003 14:32, Jochen Kunz wrote:
> On 2003.04.07 23:19 Lyle Bickley wrote:
> > Now, if I understand you correctly, every drive in the DSSI
> > "chain" will show up as a separate MSCP controller
>
> Yes.
>
> > and NetBSD defaults to only one MSCP controller.
>
> Two. There are two MSCP disk adapters in GENERIC at CSR 0172150 and
> 0160334.
>
> > Someplace (I'll have to look for it), there's a way to
> > increase the count up to 7(?).
>
> It is simple. Configure every disk at a separate CSR and include
> apropriate
> uda*=09=09at uba?=09csr <insert CSR here>=09#
> UDA50/RQDX?
> lines in the kernel config file.

--=20
Lyle Bickley
Bickley Consulting West Inc.
http://bickleywest.com
V 650-428-0621
"Black holes are where God is dividing by zero"