Subject: Re: siop problems
To: Lloyd Parkes <lloyd@must-have-coffee.gen.nz>
From: Manuel Bouyer <bouyer@antioche.lip6.fr>
List: port-sparc64
Date: 03/13/2002 10:41:01
On Mon, Mar 11, 2002 at 07:18:44PM +1300, Lloyd Parkes wrote:
> ok .properties 
> assigned-addresses       81020810 00000000 00000400 00000000 00000100 
>                          82020814 00000000 00002000 00000000 00000100 
>                          82020818 00000000 00004000 00000000 00001000 
> device_type              scsi-2
> clock-frequency          02625a00 
> reg                      00020800 00000000 00000000 00000000 00000000 
>                          01020810 00000000 00000000 00000000 00000100 
>                          02020814 00000000 00000000 00000000 00000100 
>                          02020818 00000000 00000000 00000000 00001000 
> model                    Symbios,53C875
> compatible               glm
> name                     scsi
> devsel-speed             00000001 
> class-code               00010000 
> interrupts               00000001 
> max-latency              00000040 
> min-grant                00000011 
> subsystem-vendor-id      00001000 
> subsystem-id             00001000 
> revision-id              00000014 
> device-id                0000000f 
> vendor-id                00001000 

OK, mine is:
ok .properties
assigned-addresses       81021810 00000000 00000800 00000000 00000100 
                         82021814 00000000 00004000 00000000 00000100 
                         82021818 00000000 00006000 00000000 00001000 
device_type              scsi-2
clock-frequency          02625a00 
reg                      00021800 00000000 00000000 00000000 00000000 
                         01021810 00000000 00000000 00000000 00000100 
                         02021814 00000000 00000000 00000000 00000100 
                         02021818 00000000 00000000 00000000 00001000 
model                    Symbios,53C875
compatible               glm
name                     scsi
devsel-speed             00000001 
class-code               00010000 
interrupts               00000001 
max-latency              00000040 
min-grant                00000011 
revision-id              00000026 
device-id                0000000f 
vendor-id                00001000 

They are identical exept revision ID, they should use the same entry in
siop_pci_common(). 

Please try to add some printfs in the siop_pci and siop_pci_common code to
try to find where it dies exactly.

--
Manuel Bouyer, LIP6, Universite Paris VI.           Manuel.Bouyer@lip6.fr
--