Re: envstat wrong: who's at fault?
On Jul 26, 2010, at 11:59 10AM, der Mouse wrote:
> Last night, I wrote, of the issue I had with envstat/envsys values,
>
>> One thing I have not yet done is to plot the figures to see what they
>> look like - I'm letting the battery drain to the point of the machine
>> going dead while recording this information; once that's done I'll
>> have some figures worth plotting.
>
> I've now done this. The pictures are interesting, and clearly indicate
> that the discharge rate fairly consistently under-reports the actual
> discharge rate (in terms of the reported charge values, that is; I have
> no independent measurements of either figure, so I can't tell which
> one, if either, correponds to the electrical reality).
>
How old is the battery? In my experience, as batteries age their discharge
characteristics change markedly. The hardware-reported value may not account
for that properly.