Subject: Re: T60 status: speedstep works, ACPI S1 fails, S3 locks hard
To: Greg Troxel <gdt@ir.bbn.com>
From: Manuel Bouyer <bouyer@antioche.eu.org>
List: port-i386
Date: 10/12/2006 09:24:36
On Wed, Oct 11, 2006 at 07:49:32PM -0400, Greg Troxel wrote:
> At auto, I get 100/FD on the switch (Linksys EZXS88W 10/100, never had
> trouble with anything else), and no connectivity.  (I'll denote FD vs
> - (no FD light)).  I ran tcpblast and am pretty sure the hub 10/100
> light is accurate.  Note that this is a sequence; a given media
> command doesn't always result in the particular behavior.
> 
> media 10baseT: 10/- works
> media 10baseT mediaopt full-duplex: 10/- works
> media 100baseTX: 10/- works
> media 100baseTX mediaopt full-duplex: 10/- works
> media autoselect: 100/FD FAILURE
> media 10baseT: 10/- works

What happens if you do autoselect -> 100baseTX ?
For me, autoselect -> 10baseT -> 100baseTX keeps the link at 10mb/s,
but autoselect -> 100baseTX, or
autoselect -> 10baseT -> autoselect -> 100baseTX makes it 100mb/s half
duplex as expected.

> 
> I have used the interface with auto with a Thinkpad R51 wm(4) and that
> worked at 1000baseT.
> 
> wm0 at pci2 dev 0 function 0: Intel i82573L Gigabit Ethernet, rev. 0

I'm currently hacking on wm(4), I'll see if I find something for autoneg
on this chip.

-- 
Manuel Bouyer, LIP6, Universite Paris VI.           Manuel.Bouyer@lip6.fr
     NetBSD: 26 ans d'experience feront toujours la difference
--