Subject: Re: panic due to 'fatal page fault in supervisor mode'
To: Rob Windsor <windsor@warthog.com>
From: Soren S. Jorvang <soren@wheel.dk>
List: port-i386
Date: 11/01/1999 04:25:46
On Sun, Oct 31, 1999 at 09:17:10PM -0600, Rob Windsor wrote:
> [...]
> audio0 at gus0: full duplex
> fatal page fault in supervisor mode
> trap type 6 code f0280000 eip f01fabf8 cs 8 eflags 10206 cr2 24 cpl ffffffff
> panic: trap

> Any ideas?

Someone else posted about a similar panic at gus(4) attach time.

I think there were some ad1848/gus changes recently that could be the
cause of this. You could try backing them out to see if that's it.


-- 
Soren