In article <199906181751.TAA04194@nixalsverdrus.msro.detemobil.de>,
	Jan-Hinrich Fessel <fessel@DeTeMobil.de> writes:
> Is anyone using an AST isa card or an cyclades 32Y pci successfully with 
> -current?

Not with NetBSD-current but with 1.4:

ast0 at isa0 port 0x1a0-0x1bf irq 5
com2 at ast0 slave 0: ns16550a, working fifo
com3 at ast0 slave 1: ns16550a, working fifo
com4 at ast0 slave 2: ns16550a, working fifo
com5 at ast0 slave 3: ns16550a, working fifo
ast1 at isa0 port 0x2a0-0x2bf irq 7
com6 at ast1 slave 0: ns16550a, working fifo
com7 at ast1 slave 1: ns16550a, working fifo
com8 at ast1 slave 2: ns16550a, working fifo
com9 at ast1 slave 3: ns16550a, working fifo

All ports are in use and work fine.

> both are on (different) i386, 1.4-current an 1.3I.
> ast0 at isa0 port 0x1a0-0x1bf irq 5
> com2 at ast0 slave 0: ns8250 or ns16450, no fifo
> com3 at ast0 slave 1: st16650, broken fifo
> com4 at ast0 slave 2: st16650, broken fifo
> com5 at ast0 slave 3: st16650, broken fifo

The board is really using IRQ 5 and not set to compatiblity mode? Does
something else use IRQ 5?

	Regards

-- 
Matthias Scheler                                http://home.owl.de/~tron/