On Sun, Mar 25, 2007 at 09:31:32AM -0400, Greg Troxel wrote:
>
> I was reacting to William's error message:
>
> wd2a: device timeout reading fsbn 268435392 of 268435392-268435519 (wd2 bn 268435455; cn 266305 tn 0 sn 15), retrying
> pdcsata0:0:0: lost interrupt type: ata tc_bcount: 65536 tc_skip: 0
>
> That transfer is FFFFFC0 to 1000003F, so it looks like it crosses the
> boundary. Does the code switch to LBA48 for the whole transfer? Does
> it need to be split into a non-LBA48 and a LB48 part? Perhaps the
> drive can't handle such crossings. I could be off by some power of
> two, though.
Yes, this one cross the LBA48 barrier. But in previous messages he inclued
errors with other block numbers ...
--
Manuel Bouyer <bouyer@antioche.eu.org>
NetBSD: 26 ans d'experience feront toujours la difference
--