Subject: Re: New Dell 2300 PowerEdge
To: Scott R. Burns <Scott.Burns@Netcontech.Com>
From: Manuel Bouyer <bouyer@antioche.eu.org>
List: netbsd-help
Date: 05/19/2002 17:26:54
On Sun, May 19, 2002 at 10:11:25AM -0400, Scott R. Burns wrote:
> I have just picked up a used Dell PowerEdge 2300 dual 333 machine.
> Everything is working
> fine with V1.5.2 and I see that MP operation is coming fast. I have one
> question on this
> hardware. Upon boot the following is printed:
>
> ses0 at scsibus0 target 6 lun 0: <DELL, 1x6 U2W SCSI BP, 5.35> SCSI2
> 3/processor fixed
> ses0: SAF-TE Compliant Device
>
> My research shows it to be some type of RAID or smart SCSI backplace
> controller. Is there
> a utility I can make use of this with NetBSD ? Does it say allow me to take
> a SCSI
> disk offline so I can remove/replace it why the bus active ? Is it a RAID
> controller ?
SES is "SCSI Environmental Services". From the ses(4) man page:
The environmental services class generally
are enclosure devices that provide environmental information such as num-
ber of power supplies (and state), temperature, device slots, and so on.
See sesd(8) for how to use it.
--
Manuel Bouyer <bouyer@antioche.eu.org>
--