Subject: Re: bin/36606: envstat -s does not work
To: None <,,>
From: Juan RP <>
List: netbsd-bugs
Date: 07/04/2007 17:10:07
The following reply was made to PR bin/36606; it has been noted by GNATS.

From: Juan RP <>
Subject: Re: bin/36606: envstat -s does not work
Date: Wed, 4 Jul 2007 19:08:30 +0200

 On Wed,  4 Jul 2007 17:05:00 +0000 (UTC) wrote:
 > >Description:
 > 	Since merging envsys2, envstat -s does not work.
 > % envstat -l | grep "acpibat0 charge"
 > acpibat0 charge rate
 > acpibat0 charge
 > % envstat -s "acpibat0 charge" -i 10
 > envstat: unknown sensor `acpibat0 charge'
 > % 
 If you want to use the '-s' flag, you have to use the '-d' flag too.
 Otherwise if there are sensors with the same description there's no easy
 way which to choose.
 Please see envstat(8), it's all explained there.
 Juan Romero Pardines	- The NetBSD Project	- NetBSD/pkgsrc news in Spanish