Subject: Re: ... hands up !
To: NetBSD pmax <port-pmax@netbsd.org>
From: Uwe Lienig <Uwe.Lienig@fif.mw.htw-dresden.de>
List: port-pmax
Date: 11/12/2002 15:03:44
Adam Kranzel wrote:
> 
> On Tue, 12 Nov 2002 08:34:20 +0100
> Uwe Lienig <Uwe.Lienig@fif.mw.htw-dresden.de> wrote:
> 
> > DEC Station runner!
> >
> > One out here in "new" o'Germany.
> >
> > Personal DECstation 5000/25 (MAXINE), 16MB/2.1GB, NetBSD 1.5.2
> > Personal DECstation 5000/25 (MAXINE), 16MB/1.0GB, NetBSD 1.5.2
> >          DECstation 5000/133 (3MIN),  96MB/1.6GB, NetBSD 1.5.2
> >          DECsystem 5900 (3MAXPLUS),  160MB/9.5GB, NetBSD 1.5.2
> >          DECsystem 5000/125           80MB/2.6GB  ULTRIX 4.5 0 RISC
> >          DECsystem 5100               32MB/4.7GB  ULTRIX 4.5 0 RISC
> > Personal DECstation 5000/25 (MAXINE), 16MB/1.8GB  ULTRIX 4.5 0 RISC
> >
> > These are running (since the last shutdown almost 100 days).
> >
> > Additional I have half a dozen systems in the storage.
> >
> > Nice systems with rock solid hardware, even harddisks are around 10+
> > years and in service since then.
> >
> > Keep up running these PMAXEN.
> >
> > --
> > Uwe Lienig  | fon: (+49 351) 462 2780 |
> > mailto:uwe.lienig@fif.mw.htw-dresden.de
> >             | fax: (+49 351) 462 3476 |
> >             | http://www.fif.mw.htw-dresden.de
> > HTW Dresden | parcels: Gutzkowstr. 22 | letters: PF 12 07 01
> >    -FiF-    |          01069 Dresden  |          01008 Dresden
> >
> 
> I just purchased my first two, which are a 5000/200 and a 5000/240.  I
> haven't had time to set them up yet though.
> Quick question:  Can I just use a normal RS232 null-modem cable to talk
> to the serial port on these?
> 
> thanks
>  -Adam

Yup. Settings on the DEC's are 9600,8,n,1 . Hyperterminal from a WinBox will
work, if the conn paras are set to this.

The null-modem should be wired like this.

DB-25   DB-25
DEC     PeeCee

 2---\ /---2
      X (this is to be cross conn)
 3 --/ \---3
 4-+
   |
 5-+

 6-+------20
   |
 8-+

20------+--6
        |
        +--8

7----------7

If the PeeCee has a DB-9 connector for the serial interface, a normal DB-25 ->
DB-9 converter conn should do.

At the DEC station the DB-25 conn labeled with no 3 ( has two arrows below for
I/O) is used for terminal output (I think hard wired). After plugging in
everything you should see some output at you terminal after switching on your
5k200/5k240 (depending on the ROM version it may take a while - but after 1
minute there should be a response - they behave similar in this regard).

More info is available from the PMAX port at netbsd.org - they have fairly good
docs.


-- 
Uwe Lienig  | fon: (+49 351) 462 2780 | mailto:uwe.lienig@fif.mw.htw-dresden.de
            | fax: (+49 351) 462 3476 | http://www.fif.mw.htw-dresden.de
HTW Dresden | parcels: Gutzkowstr. 22 | letters: PF 12 07 01       
   -FiF-    |          01069 Dresden  |          01008 Dresden